Changelog
2.0.3.7 (2025-11-04)
- Update the engraving number for mirror electrodes
- Optimize the export of empty STP drawings for NX2506
- Adjust the exported material list back to the weight of rough materials
- Change the deletion of nodes in electrode drawing output to batch deletion
- Adjust the export of 3D: if the file already exists, it must be overwritten for normal export
- Optimize the issue where the customer number is lost during the secondary initialization of project initialization
2.0.3.6 (2025-10-31)
- Add electrode configuration; check the box to default that the spark gap has been deducted from the body
- Add standard material specification configuration for electrodes
- For electrode drawing output, the default option for electrode contact surface analysis checks interference inspection
- Add login verification to server configuration
- Electrode BOM table remarks + processing remarks + EDM remarks
- Optimize the exclusion of R angles in electrode point extraction
- Optimize the distribution of electrode point extraction
- Add file saving configuration for drawing output
2.0.3.5 (2025-09-30)
- Add tool split body
- Add tool rib reinforcement
- Add tools for STP, X_T, and conversion to Prt
- Add tool hole bottom clearance
- Add tool top surface replacement with plane
- Add tool flatten curve
- Prompt for eccentricity of the workpiece center in drawing output
- Optimize the export of drawings
2.0.3.4 (2025-09-26)
- Add the general assembly drawing of the EDM list
- Optimize the distribution of electrode sampling points
- Add the export of a single CAM Stp
2.0.3.3 (2025-09-23)
- Add 2 specified settings for point color selection
- Optimize the prompt sequence for automatic point selection
- Optimize the STP export bug
2.0.3.1 (2025-09-19)
- Optimization of the Bug in the Height of the Electrode Dotting Reference Plane
- Adding the output of the buckle label to the electrode drawing
- Optimization of the BUG in setting the spark gap for multi-tooth electrodes
2.0.3.0 (2025-09-18)
- Optimization of discharge parameters for lost hanging reference platform
- Optimization of spark positions for multi-tooth electrodes
- Optimization of the prompting sequence for electrode point selection
2.0.2.9 (2025-09-15)
- The electrode list displays multi-station spark gaps
- Measurement report plotting in batches + automatic plotting
2.0.2.8 (2025-09-13)
- Add electrode measurement report plotting
- Import electrodes and optimize the selection of datum planes
- Optimize the BUG where the saved configuration of enumeration options does not take effect
- Display spark gaps in multi-tooth electrode drawings
2.0.2.7 (2025-09-08)
- Optimization of the BUG where exporting PDF reports a CGM path error
- Optimization of the BUG where exporting STP results in an extra 90-degree entity
2.0.2.6 (2025-09-05)
- Import of other electrodes: add Xingchuang and Jinyu, and optimize
- Update of electrode program sheet: optimization of single program
- Optimization of part naming selection
- Coordinate management: cancel the default coordinate
- Optimization of drawing output for multi-tooth electrodes
- Optimization of prompt for manual point selection in inspection
- Optimization of abnormal point exclusion in drawing output
- Modify the export of STP to background output
- Optimization of benchmark platform engraving
- Configuration of spark gap type options
- Modify the export of PDF to background output
- Selection of station engraving for multi-tooth electrodes
- Optimization of BUG in editing properties of special-shaped electrodes
2.0.2.5 (2025-08-28)
- Added electrode list
- Added the function to save the table layout on the interface
2.0.2.4 (2025-08-25)
- Added engraving deletion function
- Optimized the issue of missing processing methods when importing other electrodes
- Added multi-tooth electrode attributes
- Enabled drawing generation for multi-tooth electrodes
- Added contact surface analysis for multi-tooth electrodes
2.0.2.3 (2025-08-20)
- Added angle marking to the discharge diagram
- Optimized error prompts for benchmark table mounting
- Added interface layout saving function
- Optimized angle marking for inclined tops
- Optimized the selection of part centering surfaces in the discharge diagram
2.0.2.2 (2025-08-18)
- Optimized errors in material list submission
- Optimized the electrode import interface and electrode analysis interface
- Added upload error prompts
- Optimized the material loss issue when modifying electrode information
2.0.2.0 (2025-08-15)
- Added prompts for checking electrode datum planes during drawing generation
- Added prompts for checking tool number = 0 in the program list
- Optimized the editing of benchmark tables for special-shaped electrodes
2.0.1.9 (2025-08-14)
- Added mirror electrode function
- Added discharge drawing generation for electrodes with multi-station, multi-part, and multi-coordinate system
2.0.0.4 Update
- Optimized attribute prompts for special-shaped electrodes
- Added checks for initial mold numbers and part numbers
- Added an independent button for electrode contact surfaces
2.0.0.2 Update
- Optimized benchmark table stretching
- Added electrode contact surface analysis to electrode drawing generation
- Optimized the omission of coordinate saving for shared electrodes
- Fixed the bug where the material preparation length direction was set to X dimension